Fire Fighting Systems and Equipment in Buildings



General Fire Fighting Equipment
Fire fighting systems and equipment vary depending on the age, size, use and type of building construction. A building may contain some or all of the following features:
  • fire extinguishers
  • fire hose reels
  • fire hydrant systems
  • automatic sprinkler systems.
Fire extinguishers
Fire extinguishers are provided for a 'first attack' fire fighting measure, generally undertaken by the occupants of the building before the fire service arrives. It is important that occupants are familiar with which extinguisher type to use on which fire.
Most fires start as a small fire and may be extinguished if the correct type and amount of extinguishing agent is applied whilst the fire is small and controllable.
The principle fire extinguisher types currently available include:
Extinguishing Agent    Principle Use
Waterwood and paper fires - not electrical
Foamflammable liquid fires - not electrical
Carbon dioxideelectrical fires
Dry Chemicalflammable liquids and electrical fires
Wet chemicalfat fires - not electrical
Special Purposevarious (eg metal fires)
Fire extinguisher locations must be clearly identified. Extinguishers are colour coded according to the extinguishing agent.
It is the policy of the Community Safety and Resilience Department that fire extinguishers be logically grouped at exits from the building, so that occupants first go to the exit and then return to fight the fire, knowing that a safe exit lies behind them, away from the fire. In some instances this will be at odds with the prescriptive requirements of Australian Standard AS2444 Portable fire extinguishers and fire blankets - Selection and location, which simply specifies a distance of travel to a fire extinguisher rather than their location in relation to escape paths. Blind compliance with the standard has the potential to place the fire between the occupant and the safe escape path.
Fire hose reels
Fire hose reels are provided for use by occupants as a 'first attack' fire fighting measure but may, in some instances, also be used by firefighters.
When stowing a fire hose reel, it is important to first attach the nozzle end to the hose reel valve, then close the hose reel valve, then open the nozzle to relieve any pressure in the wound hose, then close the nozzle. This achieves two principle objectives:
  • A depressurised hose and hose reel seal will last longer than if permanently pressurised.
  • When the hose reel is next used, the operator will be forced to turn on the isolating valve, thus charging the hose reel with pressurised water supply, before being able to drag the hose to the fire. A potential danger exists if the operator reaches the fire and finds no water is available because the hose reel valve is still closed.
Because hose reels are generally located next to an exit, in an emergency it is possible to reach a safe place simply by following the hose.
In South Australia, a unique floor mounted swivel hose guide is often employed which lays the hose at floor level, prior to being dragged by the operator. In practice for a single person, this makes withdrawal of the hose much easier than does the traditional high level swinging arm hose guide.
Fire hydrant systems
Fire hydrant systems are installed in buildings to help firefighters quickly attack the fire. Essentially, a hydrant system is a water reticulation system used to transport water in order to limit the amount of hose that firefighters have to lay, thus speeding up the fire fighting process.
Fire hydrants are for the sole use of trained firefighters (which includes factory fire fighting teams). Because of the high pressures available serious injury can occur if untrained persons attempt to operate the equipment connected to such installations.
Fire hydrant systems sometimes include ancillary parts essential to their effective operation such as pumps, tanks and fire service booster connections. These systems must be maintained and regularly tested if they are to be effective when needed.
The placement of such equipment needs to closely interface with fire service operational procedure; simply complying with deemed to satisfy code provisions is a potential recipe for disaster. For any advice regarding these systems, old or new, please ask the intended users; contact the Community Safety and Resilience Department.
Automatic Sprinkler Systems
Time is essential in the control of fire. Automatic sprinkler systems are one of the most reliable methods available for controlling fires. Today's automatic fire sprinkler systems offer state of the art protection of life and property from the effects of fire. Sprinkler heads are now available which are twenty times more sensitive to fire than they were ten years ago.
A sprinkler head is really an automatic (open once only) tap. The sprinkler head is connected to a pressurised water system. When the fire heats up the sprinkler head, it opens at a pre-set temperature, thus allowing pressurised water to be sprayed both down onto the fire and also up to cool the hot smoky layer and the building structure above the fire. This spray also wets combustible material in the vicinity of the fire, making it difficult to ignite, thereby slowing down or preventing fire spread and growth.
When a sprinkler head operates, the water pressure in the system drops, activating an alarm which often automatically calls the fire service via a telephone connection.
Some people say sprinklers cause a lot of water damage. As has been explained, only those sprinkler heads heated by the fire operate; all sprinklers in a building do not operate at once. Usually non-fire water damage only occurs if the occupants carelessly damage the system. Firefighters use much more water than a sprinkler system. The combined damage from a fire and the water used by firefighters dramatically exceeds that likely from a properly installed sprinkler system.
Because, historically, complete extinguishment of fires has not been achieved, it is traditional to consider that sprinklers only control fire growth until intervention occurs by the fire service. Today, some sprinkler systems are designed for early suppression and are considered to have failed if they do not extinguish the fire.
Sprinkler systems are usually installed in high or large buildings and high fire hazard occupancies. Statistics show that in a majority of cases where sprinklers are installed the fire has been controlled by one sprinkler head alone.
For further discussion or advice on these issues, please contact the Community Safety and Resilience Department.
The following documents are recommended further reading for guidance and information:
  • The National Construction Code Volume 1 Building Code of Australia Class 2 to Class 9 Buildings
  • Australian Standard 2444.1 Portable fire extinguishers and fire blankets - Selection and location
  • Australian Standard 1851 Maintenance of fire protection equipment - Portable fire extinguishers and fire blankets
  • Australian Standard 2441 Installation of fire hose reels
  • Australian Standard 2419.1 Fire hydrant installations - System design, installation and commissioning
  • Australian Standard 2118.1 Automatic fire sprinkler systems.

মন্তব্যসমূহ

একটি মন্তব্য পোস্ট করুন

এই ব্লগটি থেকে জনপ্রিয় পোস্টগুলি

WHAT IS FIRE RATED GYPSUM DRYWALL?

Gypsum is approximately 21 percent by weight chemically combined water which greatly contributes to its effectiveness as a fire resistive barrier. When gypsum drywall is exposed to fire, the water is slowly released as steam, effectively retarding heat transmission. Fire rated gypsum drywall is more fire resistant because it contains glass fiber reinforcement and other additives within its specially formulated gypsum core to help it hold up longer to a fire exposure. Fire  rated drywall is referred to as “Type X” and must be third-party certified by an independent testing and listing agency such as UL (Underwriters Laboratories Inc.) and ULC (Underwriters’ Laboratories of Canada) to meet the fire performance requirements prescribed in the ASTM C1396 (CAN/CSA-A82.27) Standard Specification for Gypsum Board. Types of Fire Rated Gypsum: Type X fire rated gypsum drywall that is 5/8 -inch (15.9mm) thick and installed on each side of nominal 2-inch x 4-inch (38x89mm) ...

Pipe Schedule Method for Firefighting Sprinkler System

Pipe Schedule Method for Firefighting Sprinkler System                                     Pipe Schedule Method for Firefighting Sprinkler System  The water demand for firefighting sprinkler systems shall be determined by either the pipe schedule method or the hydraulic calculation method, in this article we will discuss the pipe schedule method. What is pipe schedule system?! According to NFPA 13, Pipe Schedule System is defined as sprinkler system in which the pipe sizing is selected from a schedule that is determined by the occupancy classification and in which a given number of sprinklers are allowed to be supplied from specific sizes of pipe. Where can we use pipe schedule method?! New systems of 465 m2 or less. Additions or modifications to existing pipe schedule systems. Classification of occupancies according to hazard NFPA 13 classifies the occupa...